{"id":8530,"date":"2022-05-30T11:16:50","date_gmt":"2022-05-30T11:16:50","guid":{"rendered":"https:\/\/shop.fst.co.za\/staging\/?p=8530"},"modified":"2022-06-01T08:10:22","modified_gmt":"2022-06-01T08:10:22","slug":"conventional-vs-addressable-fire-alarm-systems","status":"publish","type":"post","link":"https:\/\/shop.fst.co.za\/staging\/conventional-vs-addressable-fire-alarm-systems\/","title":{"rendered":"Conventional vs Addressable Fire Alarm Systems"},"content":{"rendered":"<h1><span style=\"font-weight: 400;\">Conventional vs Addressable Fire Alarm Systems<\/span><\/h1>\n<p><span style=\"font-weight: 400;\">Fire alarm systems consist of a network of connected devices installed throughout a premises. These devices include <\/span><a href=\"https:\/\/shop.fst.co.za\/staging\/product-category\/heat-smoke-point-detection\/\"><span style=\"font-weight: 400;\">smoke and heat detectors<\/span><\/a><span style=\"font-weight: 400;\"> that sense for fires, as well as <\/span><a href=\"https:\/\/shop.fst.co.za\/staging\/product-category\/warning-devices\/sounders\/\"><span style=\"font-weight: 400;\">fire alarm sounders<\/span><\/a><span style=\"font-weight: 400;\"> and <\/span><a href=\"https:\/\/shop.fst.co.za\/staging\/product-category\/warning-devices\/fire-bells\/\"><span style=\"font-weight: 400;\">fire bells<\/span><\/a><span style=\"font-weight: 400;\"> that warn occupants of the presence of a potential fire.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">There are two main types of fire alarm systems &#8211; Conventional Fire Alarm Systems and Addressable Fire Alarm Systems. This post will explore both types of fire alarm systems to help understand the functional differences between these two systems.\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<h1><span style=\"font-weight: 400;\">What is a Conventional Fire Alarm System?<\/span><\/h1>\n<figure id=\"attachment_8531\" aria-describedby=\"caption-attachment-8531\" style=\"width: 388px\" class=\"wp-caption alignleft\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8531\" src=\"https:\/\/shop.fst.co.za\/staging\/wp-content\/uploads\/2022\/05\/Conventional-Fire-Alarm-System.jpg\" alt=\"Conventional Fire Alarm Wiring Diagram\" width=\"388\" height=\"250\" \/><figcaption id=\"caption-attachment-8531\" class=\"wp-caption-text\"><em>Conventional Fire Alarm Wiring Diagram<\/em><\/figcaption><\/figure>\n<p><span style=\"font-weight: 400;\">Conventional systems are relatively older fire alarm systems that are based on analogue technology. They are generally suited for smaller applications, such as fire alarm systems in small offices, shops, restaurants, and residential properties.<\/span><\/p>\n<p>Conventional fire alarm systems make use of one or more circuits (wired connections) that connect sensors, detectors, and devices to a <a href=\"https:\/\/shop.fst.co.za\/staging\/product-category\/extinguishing-panels\/\"><span style=\"font-weight: 400;\">fire alarm control panel<\/span><\/a><span style=\"font-weight: 400;\">. Each circuit represents an area or zone that these linked devices cover.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Conventional fire alarm systems are able to link multiple <\/span><a href=\"https:\/\/shop.fst.co.za\/staging\/product-category\/warning-devices\/\"><span style=\"font-weight: 400;\">devices<\/span><\/a><span style=\"font-weight: 400;\"> on a single circuit, however, these systems cannot tell which device has been activated within a circuit. This means that it can identify a fire within a zone, but cannot determine the exact location of the fire within that zone.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h1><\/h1>\n<h1><\/h1>\n<h1><span style=\"font-weight: 400;\">What Is An Addressable Fire Alarm System?<\/span><\/h1>\n<figure id=\"attachment_8532\" aria-describedby=\"caption-attachment-8532\" style=\"width: 385px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8532\" src=\"https:\/\/shop.fst.co.za\/staging\/wp-content\/uploads\/2022\/05\/Addressable-Fire-Alarm-System.jpg\" alt=\"Addressable Fire Alarm System Diagram\" width=\"385\" height=\"258\" \/><figcaption id=\"caption-attachment-8532\" class=\"wp-caption-text\"><em>Addressable Fire Alarm System Diagram<\/em><\/figcaption><\/figure>\n<p><span style=\"font-weight: 400;\">Addressable fire alarm systems are modern systems that use digital technology to transfer information from networked devices to the main <\/span><a href=\"https:\/\/shop.fst.co.za\/staging\/product-category\/extinguishing-panels\/\"><span style=\"font-weight: 400;\">fire alarm control panel<\/span><\/a><span style=\"font-weight: 400;\">. These systems use binary code (combinations of zeros and ones) to allow linked devices to communicate with the main control panel.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">As the name suggests, addressable fire alarm systems allow you to assign a unique address\/code to each <\/span><a href=\"https:\/\/shop.fst.co.za\/staging\/product-category\/warning-devices\/\"><span style=\"font-weight: 400;\">device<\/span><\/a><span style=\"font-weight: 400;\"> installed on the system. This means that addressable fire alarm system<\/span>s are able to determine the exact location of a fire by identifying the individual device that has been triggered.<\/p>\n<p><span style=\"font-weight: 400;\">All of the devices in an addressable fire alarm system connect to the fire alarm control panel in a wired loop configuration. Addressable fire alarm systems make use of a single wired circuit to connect all networked devices, as seen in the accompanying diagram.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h1><\/h1>\n<h1><span style=\"font-weight: 400;\">The Difference Between Conventional And Addressable Fire Alarm Systems<\/span><\/h1>\n<p><span style=\"font-weight: 400;\">The key differences between conventional fire alarm systems and addressable fire alarm systems can be summarised as follows:<\/span><\/p>\n<h2><span style=\"text-decoration: underline;\"><span style=\"font-weight: 400;\">Wiring<\/span><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">All of the devices in an addressable fire alarm system connect to the main control panel via a single shared wire loop that runs through the entire premises. Whereas conventional fire alarm systems require each networked device to connect to the main control panel via its own dedicated <\/span><a href=\"https:\/\/shop.fst.co.za\/staging\/product\/fire-resistant-cables\/\"><span style=\"font-weight: 400;\">fire resistant wire<\/span><\/a><span style=\"font-weight: 400;\">, rather than a shared one. Conventional systems require more cabling than addressable systems, making the installation process a lot more tedious in comparison.<\/span><\/p>\n<h2><span style=\"text-decoration: underline;\"><span style=\"font-weight: 400;\">Location Detection<\/span><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Addressable fire alarm systems are able to pinpoint the exact location of a fire by identifying the individual device that triggered an alarm. In the event of a false alarm, addressable systems can determine the faulty device that activated the alarm.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Conventional alarm systems cannot identify the exact device that triggered an alarm. These systems are more suited for smaller facilities where pinpointing the exact location of a fire becomes unnecessary.<\/span><\/p>\n<h2><span style=\"text-decoration: underline;\"><span style=\"font-weight: 400;\">Cost<\/span><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Addressable fire alarm systems offer more advanced functionality and are therefore more expensive to purchase than conventional fire alarm systems. However, addressable alarm systems can work out to be more cost-efficient in the long run when installation, maintenance, and upgrade costs are considered.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">While conventional fire alarm systems may cost less to purchase, the extensive wiring involved in installing these systems results in them being more expensive to install than addressable fire alarm systems.<\/span><\/p>\n<h2><span style=\"text-decoration: underline;\"><span style=\"font-weight: 400;\">Reliability<\/span><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Addressable fire alarm systems are generally considered to be more reliable than conventional systems due to the way in which these systems are wired to connect to the main control panel.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Conventional fire alarm systems are wired to connect to the control panel only at one end. This means that if the wire gets damaged or severed, a device&#8217;s signal cannot be transmitted to the control panel and the device will become disconnected.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Addressable fire alarm systems are wired to connect to the control panel at two ends in a loop. This means that if one end of the wired loop gets damaged or severed, a device\u2019s signal can still be sent to the control panel via the other end of the wired loop.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h1><span style=\"font-weight: 400;\">FST Fire Alarm Systems<\/span><\/h1>\n<p><a href=\"https:\/\/www.fst.co.za\/\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: 400;\">Fire and Security Techniques<\/span><\/a><span style=\"font-weight: 400;\"> is an authorised supplier of high-tech fire detection systems and fire alarm systems. We provide comprehensive fire protection solutions for all types of properties and working facilities.<\/span><\/p>\n<p><a href=\"https:\/\/shop.fst.co.za\/staging\/contact-us\/\"><span style=\"font-weight: 400;\">Contact Us<\/span><\/a><span style=\"font-weight: 400;\"> for conventional and addressable fire alarm systems suited to your unique fire protection needs. <\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Conventional vs Addressable Fire Alarm Systems Fire alarm systems consist of a network of connected devices installed throughout a premises. These devices include smoke and heat detectors that sense for fires, as well as fire alarm sounders and fire bells that warn occupants of the presence of a potential fire. There are two main types [&hellip;]<\/p>\n","protected":false},"author":34,"featured_media":8533,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[465],"tags":[466,467],"class_list":["post-8530","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-alarm-systems","tag-alarm-systems","tag-fire-alarms"],"featured_image_src":{"landsacpe":["https:\/\/shop.fst.co.za\/staging\/wp-content\/uploads\/2022\/05\/Fire-Alarm-System.jpg",1,1,false],"list":["https:\/\/shop.fst.co.za\/staging\/wp-content\/uploads\/2022\/05\/Fire-Alarm-System.jpg",1,1,false],"medium":["https:\/\/shop.fst.co.za\/staging\/wp-content\/uploads\/2022\/05\/Fire-Alarm-System.jpg",1,1,false],"full":["https:\/\/shop.fst.co.za\/staging\/wp-content\/uploads\/2022\/05\/Fire-Alarm-System.jpg",0,0,false]},"_links":{"self":[{"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/posts\/8530","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/comments?post=8530"}],"version-history":[{"count":12,"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/posts\/8530\/revisions"}],"predecessor-version":[{"id":8546,"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/posts\/8530\/revisions\/8546"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/media\/8533"}],"wp:attachment":[{"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/media?parent=8530"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/categories?post=8530"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shop.fst.co.za\/staging\/wp-json\/wp\/v2\/tags?post=8530"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}